Karl
€ 219.00
Product information Karl
Powerful yet quiet! Karl is the first of a new generation of efficient humidifiers. Despite his low power consumption, the compact evaporator can humidify large rooms in no time at all. Karl has intelligent functions such as an Auto mode and is very easy to operate. His elegant design looks fresh and light. It fits wonderfully into any living environment. For undisturbed sleep, Karl’s LED function lights can be dimmed or switched off altogether.
Important purchasing advice
We recommend a more powerful humidifier for Minergie houses (low energy or passive houses) or apartments for which calculations should be based on twice the room size.
The reason for this lies in the continuous exchange of air: cold and dry outdoor air is heated up and channelled indoors. The moisture produced by people, animals, furniture, plants, cooking, showering, etc. is quickly directed outside by the continuous exchange of air, usually resulting in extremely dry air indoors. Controlled ventilation systems therefore have the same effect as open windows.
Product family | Humidifier |
---|---|
System | Evaporator |
Color | black |
Accessories (included) | 1 Water Cube, 2 humidifier filters |
Room size m² | 100 |
Room size m³ | 250 |
Capacity | 690 g/h |
Power level | 4 |
Power consumption | 1.4 – 30 W |
Water tank capacity | 4 l |
Noise level | 27 – 59 dB(A) |
Weight | 2.5 kg |
Dimensions | 296 x 304 x 212 mm |
Awards
Instruction manual and more
Video tutorials
Auto mode
Karl automatically selects the appropriate humidification level in auto mode to reach and maintain the desired humidity quietly and efficiently.
Easy handling
The 4-liter water container can be easily filled through a flap opening on the top, even during operation. When the water container is empty, Karl switches off automatically.
Simple operation
All functions of humidifier Karl can be conveniently controlled on the unit or via Wi-Fi using the Stadler Form app - including monitoring of the current humidity. This ensures an optimal indoor climate at home even when you are on the move.
Good to know
Find important information here
For the hygienic and optimal use of the humidifier, the humidifier filter should be replaced at least every two months. If you continue to use the humidifier filter for longer than this, on the one hand the humidification output may deteriorate significantly and on the other, the antibacterial action of the filter can no longer be guaranteed. You can generally purchase humidifier filters from the place where you bought your device. The filter change indicator has to be reset manually after changing the filters.
Discolouration which is slightly yellowish or brownish is normal. Discolouration is caused by the substances in the mains water or the air. The poorer the water quality, the quicker the humidifier filter will become discoloured. Although this does not look pleasant, it is harmless as long as it is not due to mould. The discolouration will not affect the performance of your humidifier either. If you have not been using the humidifier filter for very long, you can rinse it thoroughly, turn it over and reuse it. If the humidifier filter is more than 2 months old, we recommend that you replace it.
It is also possible for the top part of the humidifier filters to become hard. During the evaporation process, the lime present in the water is collected in the humidifier filter as limescale. The harder the water, the quicker the humidifier filter will become hard. If you use water from a water softener which operates based on the principle of ion exchange, salt may collect in the humidifier filter rather than limescale. If you have been using the humidifier filter for less than 2 months, you can rinse it thoroughly with water, turn it over and put it back again. It is possible that you may notice an odour after you have turned over the humidifier filter depending on how contaminated the filter is by constituents in the air or the water.
If your Karl or the humidifier filters smell unpleasant, there may be various reasons for this: water and air quality, a worn-out filter or even the fact that you have not used your Karl for a long time and he has still water in his tank. In any case, we recommend that you clean and descale the device thoroughly. If you have been using the filter for less than 2 months, you can rinse it thoroughly with cold, clean water, turn it over and continue to use it.
It may be that your external hygrometer and Karl are measuring different values because the devices have been positioned in different places (heights) in the room. Different humidity values will be measured depending on the air flow and temperature in each case. A tolerance of +/- 5 % is normal depending on the type of device. Karl measures the humidity levels best if he is positioned in the middle of the room so that the room air can flow towards the sensor as freely as possible. If that is not possible, we recommend positioning Karl against the wall, with a clearance of at least 30 cm. Under no circumstances should Karl be “hidden” in a corner of the room or behind a sofa/piece of furniture because this can have a negative effect on humidity measurement as well as humidification efficiency.
Ideally, you fill your Karl using the top filling opening. Of course, you can also fill Karl at the tap, but then you must be extra careful that no water spills during transportation.
Ideally, you fill it using the top filling flap. Of course, you can also fill the humidifier at the tap, but you must be very careful not to spill any water during transport.
Set the output to the highest level.
For the room size to be right, not only the room height (standard 2.5 m) but also whether or not the doors to the room are closed is a determining factor. If the doors to the room are left open, the adjacent rooms will also be included in the total area. If the relative humidity is low (below 35%), the humidity will not increase immediately. That is because the floors, furniture and walls absorb the moisture first before it ends up in the air. It can take up to two weeks for everything to absorb sufficient moisture for the humidity to start rising. As long as you keep having to top up the water regularly, your Karl is working properly.
If the humidifier filters are more than 2 months old or the upper part is hard and no longer saturated with water, the filters should be replaced.
Accessories
€ 63.70
Save € 4.70
€ 98.00
Save € 3.00
Karl
Reviews
Perfekt
Karl erfüllt sowohl ästhetisch als auch funktional unsere Erwartungen. In Kombination mit der perfekten Kaufabwicklung und dem sehr schnellen Versand resultiert somit eine uneingeschränkte Kaufempfehlung.
Review from Michael von Gunten at 07.02.2023Viel Power
Schön ist er, aber auch sehr leistungsfähig. Bei mir reicht Karl für mein ganzes Wohnzimmer, welches sicher 80 Quadratmeter gross ist. Ich glaube, er könnte auch noch mehr befeuchten. Die Einfüllöffnung ist eher etwas klein und schwierig zu treffe...
Review from Max at 18.11.2022Karl
The Designer
Since the very start, I have had the privilege to co-develop and design products for Martin Stadler and the Stadler Form Team. What began with Fred, has grown into an attractive, small but fine range of products. This experience, and being part of the team, has greatly enriched myself and my work as a designer ...